994 resultados para HIGH RESOLUTION GAS CHROMATOGRAPHY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A procedure for the determination of seven indicator PCBs in soils and sediments using microwave-assisted extraction (MAE) and headspace solid-phase microextraction (HS-SPME) prior to GC-MS/MS is described. Optimization of the HS-SPME was carried out for the most important parameters such as extraction time, sample volume and temperature. The adopted methodology has reduced consumption of organic solvents and analysis runtime. Under the optimized conditions, the method detection limit ranged from 0.6 to 1 ng/g when 5 g of sample was extracted, the precision on real samples ranged from 4 to 21% and the recovery from 69 to 104%. The proposed method, which included the analysis of a certified reference material in its validation procedure, can be extended to several other PCBs and used in the monitoring of soil or sediments for the presence of PCBs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Supercritical fluid extraction with CO2, Performed in a home-made system, of rhizomes of Dorstenia bryoniifolia Mart. ex Miq. (Moraceae) and of bark roots of Brosimum gaudichaudii Trecul (Moraceae) afforded crude extracts that were analysed by high resolution gas chromatography (HRGC). The D. bryoniifolia extract contained, besides the previously reported pimpinelin and isobergapten, the furocoumarins psoralen, bergapten, isopimpinelin and the triterpenes alpha- and beta-amyrin and the acetate of the latter. The B. gaudichaudii extract contained a number of terpenoids as well as the previously reported psoralen and bergapten. Supercritical fluid extraction gave extracts qualitatively similar to those obtained by Soxhlet extraction with hexane and, together with off-line HRGC, was shown to be a fast and accurate technique to be used in rapid phytochemical examination.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This conference, held 14-18 September 1981, addressed many aspects of high resolution molecular spectroscopy. Measurement techniques for remotely identifying trace gases in the atmosphere were discussed. Instrumentation for highly accurate and precise measurement of molecular emissions were described. The objective of the colloquium was to bring together molecular spectroscopists working in different regions of the electromagnetic spectrum from the ultraviolet to radio frequencies. These scientists shared a common interest in high resolution gas phase spectra and their analyses. The objective was met through the presentation of about 20 invited papers and many more contributed papers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A fast and efficient procedure was elaborated to identify the alkaloid constituents from Tabernaemontana hilariana (Apocynaceae). The strategy based on fractioning of the crude alkaloid fraction in small silica cartridges followed by thin-layer chromatography (TLC), capillary gas chromatography-flame ionization detection as well as high-resolution gas chromatography-mass spectrometry afforded voacangine, coronaridine, ibogamine, voacangine pseudoindoxyl, voacangine hydroxyindolenine, 3-hydroxycoronaridine and 3-(2-oxopropyl)coronaridine. (C) 1997 Elsevier B.V. B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A contaminação do ar e do meio ambiente por combustíveis derivados de petróleo tem sido objeto de crescente pesquisa no Brasil. Dentre os tipos de poluição ao meio ambiente, a poluição atmosférica é a que causa mais incômodo à população. Esta exerce efeitos sobre a saúde humana, causando desde simples irritações até câncer de pulmão. Dos poluentes mais perigosos encontrados nesses ambientes, são destaques os hidrocarbonetos e os compostos monoaromáticos como o benzeno, tolueno e xilenos (BTX), presentes nesses combustíveis, que são extremamente tóxicos à saúde humana. Para controle desses compostos orgânicos voláteis, é necessário quantificá-los e compará-los aos valores limites de tolerância legislados no Brasil. A utilização da técnica de cromatografia gasosa e da técnica de espectroscopia por infravermelho permite realizar essa tarefa de maneira relativamente simples e rápida. Portanto o objetivo deste trabalho foi apresentar a composição química de amostras de gasolina do tipo C comercializadas nos postos revendedores da Região Metropolitana do Estado do Rio de Janeiro. Foram feitas análises quantitativas dos principais grupos químicos (parafínicos, olefínicos, naftênicos e aromáticos) e etanol por Cromatografia Gasosa de Alta Resolução e da composição de benzeno, tolueno e xileno (BTX) pela técnica de absorção no infravermelho. Os resultados foram comparados com os limites dados pela especificação da ANP (Portaria n 309) para a qualidade da gasolina, com o objetivo de se verificar se estão em conformidade com este agente regulamentador. Os resultados mostraram que todos os teores encontrados de olefínicos e aromáticos foram abaixo do limite especificado. Alguns postos apresentaram os teores de benzeno acima do limite especificado, indicando um nível de ação por parte da ANP principalmente pela ação tóxica do benzeno

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To investigate the environmental levels and profiles of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs), polybrominated diphenyl ethers (PBDEs), and polychlorinated biphenyls (PCBs), tree bark samples (n = 22) were collected from Luqiao, an E-waste recycling area, in east China in July 11-13, 2006. The average concentrations of PCDD/Fs, PBDEs, and PCBs determined by isotope dilution-high resolution gas chromatography (HRGC) coupled with high resolution mass spectrometer (HRMS) were 0.1 +/- 0.0, 1.4 +/- 0.2, and 6.5 +/- 0.8 lg g (1) lipid weight, respectively. PCDD/F-toxic equivalent (TEQ, WHO-1998), PCB-TEQs, and total dioxin-like TEQs were 1.3 +/- 0.1, 0.5 +/- 0.0, and 1.8 +/- 0.2 ng g (1) lipid weight, respectively. The profiles of these pollutants in the tree bark were also discussed. Tetra-CDFs, deca-BDE and tri-CBs were the main homologues and accounted for 47% of total PCDD/Fs, 79.3% of total PBDEs, and 33.2% of total PCBs, respectively; As for TEQs, 2,3,4,7,8-PeCDF and PCB126 were the main contributors and accounted for 36% of the total PCDD/F-TEQs and 81.2% of the total PCB-TEQs, respectively. High accumulation of PCDD/Fs, PBDEs, and PCBs detected in the tree bark indicated heavy contaminations of these pollutants in Luqiao area. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface sediments and bivalves were collected from the Changjiang Estuary in December 2003 and November 2004, respectively. Polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) in these samples were measured with high-resolution chromatography (HRGC)/High Resolution Mass Spectrometer (HRMS). The concentrations of total PCDD/Fs and toxic equivalent (TEQ) were 169.83 +/- 119.63 and 0.81 +/- 0.36 pg/g dry weight (dw) in sediments, and 580.33 +/- 240.17 and 7.24 +/- 3.65 pg/g dw in bivalves. The homolog compositions of PCDD/Fs were similar among samples, the most abundant congener was octa-chlorinated dibenzo-p-dioxin (OCDD) and then octa-chlorinated dibenzofuran (OCDF) and 1,2,3,4,6,7,8-hepta-chlorinated dibenzo-p-dioxin (HOCDD). The herbicide pentachlorophenol (PCP) and sodium pentachlorophenol (Na-PCP) were proved the main source of PCDD/Fs in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aryl hydrocarbon (Ah) receptor (Ah-agonist) effects of environmental samples containing polychlorinated aromatic hydrocarbons were evaluated using a 7-ethoxyresorufin-O-deethylase (FROD) assay of a primary hepatocyte culture from grass carp (Ctenopharyngodon idellus). The results were compared with those obtained from the assay using the rat hepatoma cell line H4IIE and chemical analysis using high-resolution gas chromatography/high-resolution mass spectrometry (HRGC/HRMS). A dose-response relationship was observed between the EROD activities, either from primary hepatocyte culture assay or from H4IIE assay, and concentrations of 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). The results showed that the assay based on the H4IIE cell line (EC50 = 0.83 mug/mL) is more sensitive to TCDD than the assay based on primary hepatocyte Culture (EC50 = 9.7 pg/mL). In tests of environmental samples, the results from the assay using primary hepatocyte culture were comparable to those from the assay using the H4IIE cell line and chemical analysis of concentrations of mixtures of polychlorinated dibenzo-p-dioxin and dibenzofuran (PCDD/PCDF). The lack of a change in the activities of glutathione-S-transferase (GST) and lactate dehydrogenase (LDH) in cell culture upon exposure to TCDD indirectly indicates that the compound is persistent to biodegradation in the cell culture system. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

By using modern techniques of isotope dilution, high-resolution gas chromatography/high-resolution mass spectrometry and multiple ions detection, an effective cleanup, qualitative and quantitative method was developed for polychlorinated dibenzo-p-dioxins/furans (PCDD/F) and polychlorinated biphenyls analysis. Based on the chromatographic relative retentions of PCDD/F, a software was established for automatic peak recognition of all the isomers from tetra- to octachlorine PCDD/F. It ensured good reliability and accuracy of the analytical data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A software has been developed for the peak recognition of 136 polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) after high resolution gas chromatography coupled with mass spectrometry (HRGC/HRMS). Based on the retention times of C-13 labelled 2,3,7,8-substituted PCDD/F internal standards, the retention times of all PCDD and PCDF can be calibrated automatically and accurately. Therefore, it is very convenient to identify the peaks by comparing the retention of samples and the calibrated retention times of their chromatograms. Hence, this approach is very significant because it is impossible to obtain always a standard chromatogram and PCDD/F analysis are very expensive and time consuming. The calibration results can be transferred to Excel for calculation. The approach is a first step to store costly and environmentally relevant data for future application.